{"id":597,"date":"2018-06-15T13:04:21","date_gmt":"2018-06-15T12:04:21","guid":{"rendered":"http:\/\/www.essbilbao.org\/?page_id=597"},"modified":"2018-10-16T08:41:47","modified_gmt":"2018-10-16T06:41:47","slug":"vacuum","status":"publish","type":"page","link":"https:\/\/www.essbilbao.org\/es\/capabilities\/laboratories\/vacuum\/","title":{"rendered":"Vacuum"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row full_width=\u00bbstretch_row\u00bb content_placement=\u00bbmiddle\u00bb parallax=\u00bbcontent-moving\u00bb css_animation=\u00bbfadeIn\u00bb css=\u00bb.vc_custom_1528279765751{background-color: rgba(255,255,255,0.21) !important;*background-color: rgb(255,255,255) !important;}\u00bb][vc_column]<div class=\"fancy_heading fancy_heading_line\"><div class=\"fh-top\"><\/div><h1 class=\"title \">Vacuum<\/h1><\/div>\n[vc_row_inner][vc_column_inner width=\u00bb5\/12&#8243;]<div class=\"cq-ihover  cq-style-darkgray cq-ihover-bordernone\"  data-effect=\"effect8\" data-shape=\"circle\" data-bgcolor=\"\" data-titlesize=\"\" data-titlecolor=\"\" data-descsize=\"\" data-desccolor=\"\" data-iconsize=\"\" data-iconcolor=\"\" data-containerwidth=\"300\" data-captionmargintop=\"\" data-videowidth=\"\" data-bgstyle=\"darkgray\"><div class=\"cq-ihover-container\"><div class='cq-ihover-item circle effect8 right_to_left scale_up'><a href='#' class='ihover-nothing'><div class='cq-ihover-imagecontainer'><div class='cq-ihover-imageitem'><img src='https:\/\/www.essbilbao.org\/wp-content\/uploads\/2018\/09\/circulo-labs.jpg' alt='' class='cq-ihover-image' \/><\/div><\/div><div class='info-container'><div class='cq-ihover-info'><div class='cq-ihover-text'><h3><span class='cq-ihover-title cq-title-solid'>Vacuum<\/span><\/h3><p class=\"cq-ihover-icontext\"><i class=\"cq-ihover-icon entypo-icon entypo-icon-export\"><\/i><\/p><\/div><\/div><\/div><\/a><\/div><\/div><\/div>[\/vc_column_inner][vc_column_inner width=\u00bb7\/12&#8243; css=\u00bb.vc_custom_1531228729012{padding-top: 60px !important;}\u00bb][vc_column_text]The Vacuum Lab has the capabilities to ensure the compatibility and correct operation of all the components that will work in a Ultra High Vacuum environment (&lt;10-7 mbar).[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_text_separator title=\u00bbCHARACTERISTICS\u00bb i_type=\u00bbmaterial\u00bb i_icon_material=\u00bbvc-material vc-material-control_point\u00bb i_color=\u00bbcustom\u00bb title_align=\u00bbseparator_align_left\u00bb align=\u00bbalign_left\u00bb color=\u00bbwhite\u00bb add_icon=\u00bbtrue\u00bb i_custom_color=\u00bb#c22630&#8243;][vc_text_separator title=\u00bbVacuum gauge calibration by direct comparison with a reference Gauge\u00bb i_type=\u00bbmaterial\u00bb i_icon_material=\u00bbvc-material vc-material-control_point\u00bb i_color=\u00bbcustom\u00bb i_size=\u00bbsm\u00bb title_align=\u00bbseparator_align_left\u00bb align=\u00bbalign_left\u00bb add_icon=\u00bbtrue\u00bb][vc_column_text]<\/p>\n<ul class=\"specialbullet\">\n<li>The Calibration of the vacuum gauge is done by exposing both gauges (Reference and Under Calibration) to the same pressure (density and velocity distribution ) of calibration gas molecules.<\/li>\n<li>The calibration chamber is pumped down by a Diaphragm pump and Turbomolecular pump (Leybold TurboLab 80), the reference gauge is a combo of a Bayard Alpert hot cathode and a Pirani gauge (Leybold ITR90), the gas pressure inside can be varied by a the Dosing Valve (VAT 21124-KE0X).<\/li>\n<li>The calibration is made following the ISO 3567:2011 in the pressure range between 5*10-7 mbar to 5*10-5mbar.<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=\u00bb1\/2&#8243;][vc_single_image image=\u00bb3013&#8243; img_size=\u00bblarge\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bblink_image\u00bb][\/vc_column_inner][vc_column_inner width=\u00bb1\/2&#8243;][vc_single_image image=\u00bb3227&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bblink_image\u00bb][vc_single_image image=\u00bb3224&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bblink_image\u00bb][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_text_separator title=\u00bbLeak detection testing\u00bb i_type=\u00bbmaterial\u00bb i_icon_material=\u00bbvc-material vc-material-control_point\u00bb i_color=\u00bbcustom\u00bb i_size=\u00bbsm\u00bb title_align=\u00bbseparator_align_left\u00bb align=\u00bbalign_left\u00bb add_icon=\u00bbtrue\u00bb][vc_column_text]<\/p>\n<ul class=\"specialbullet\">\n<li>The leak testing used is the Tracer Gas method \u2013 Total; according to the EN 1779 \u2013 A1.<br \/>\nIn this test a pressure difference is created across the boundary of the object to be tested, this is obtained by evacuation of the object to be tested (vacuum vessel). Once the vessel is under vacuum the Tracer gas (helium) is applied to the external surface enclosing the object totally in a plastic bag.<\/li>\n<li>The vacuum chamber is pumped down by a Primary and Turbomolecular pump (Pfeiffer ACP15 &amp; HiPace700), once the required pressure is achieved the primary pump is isolated and is substituted by the Leak Detector (Leybold PhoeniX L 300) and Calibrated External Leak (INFICON TL7).<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=\u00bb1\/2&#8243;][vc_single_image image=\u00bb3016&#8243; img_size=\u00bblarge\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bblink_image\u00bb css=\u00bb.vc_custom_1535371435985{padding-top: 30px !important;}\u00bb][\/vc_column_inner][vc_column_inner width=\u00bb1\/2&#8243;][vc_single_image image=\u00bb3019&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bblink_image\u00bb css=\u00bb.vc_custom_1535371478841{padding-top: 30px !important;}\u00bb][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_text_separator title=\u00bbOutgassing Test\u00bb i_type=\u00bbmaterial\u00bb i_icon_material=\u00bbvc-material vc-material-control_point\u00bb i_color=\u00bbcustom\u00bb i_size=\u00bbsm\u00bb title_align=\u00bbseparator_align_left\u00bb align=\u00bbalign_left\u00bb add_icon=\u00bbtrue\u00bb][vc_column_text]<\/p>\n<h6>The outgassing Rate<\/h6>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<ul class=\"specialbullet\">\n<li>A measurement of the pressure increase of a sample inside a Test chamber is taken after 20 hours of pumping down and after is suddenly isolated from the pumps.<\/li>\n<li>The vacuum chamber is pumped down by a Primary and Turbomolecular pump (Pfeiffer ACP15 &amp; HiPace700), the pressure is registered by a combo of a Bayard Alpert hot cathode and a Pirani gauge (Leybold ITR90) and the isolation is made by an all-metal angle valve (VAT 54132-GE02).<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_single_image image=\u00bb3025&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bblink_image\u00bb][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h6>%HC Outgassing<\/h6>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<ul class=\"specialbullet\">\n<li>A measurement of the mass spectrum of the vacuum chamber is taken over the mass range of 1-100 uma. The measurement can be taken at any time and any pressure if the system is below the 5*10-6 mbar.<\/li>\n<li>The outgassing rate due to hydrocarbon (%HC) is to be calculated as follows:\n<ul class=\"specialbullet\">\n<li>%HC = Sum of peaks above 40 uma\/ sum of all peaks.<\/li>\n<li>The vacuum chamber is pumped down by a Primary and Turbomolecular pump (Pfeiffer ACP15 &amp; HiPace700), the pressure is registered by a combo of a Bayard Alpert hot cathode and a Pirani gauge (Leybold ITR90) and the mass spectrum is taken by General Purpose Residual Gas Analyzer (MKS e-Vision 2).<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_single_image image=\u00bb3221&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bblink_image\u00bb][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row full_width=\u00bbstretch_row\u00bb content_placement=\u00bbmiddle\u00bb parallax=\u00bbcontent-moving\u00bb css_animation=\u00bbfadeIn\u00bb css=\u00bb.vc_custom_1528279765751{background-color: rgba(255,255,255,0.21) !important;*background-color: rgb(255,255,255) !important;}\u00bb][vc_column][vc_row_inner][vc_column_inner width=\u00bb5\/12&#8243;][\/vc_column_inner][vc_column_inner width=\u00bb7\/12&#8243; css=\u00bb.vc_custom_1531228729012{padding-top: 60px !important;}\u00bb][vc_column_text]The Vacuum Lab has the capabilities to ensure the compatibility and correct<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":581,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-597","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.essbilbao.org\/es\/wp-json\/wp\/v2\/pages\/597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.essbilbao.org\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.essbilbao.org\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.essbilbao.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.essbilbao.org\/es\/wp-json\/wp\/v2\/comments?post=597"}],"version-history":[{"count":0,"href":"https:\/\/www.essbilbao.org\/es\/wp-json\/wp\/v2\/pages\/597\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.essbilbao.org\/es\/wp-json\/wp\/v2\/pages\/581"}],"wp:attachment":[{"href":"https:\/\/www.essbilbao.org\/es\/wp-json\/wp\/v2\/media?parent=597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}